logo
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.
produtos
produtos
Para casa > produtos > Sistema de supressão de gases FM200 > Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

Detalhes do produto

Lugar de origem: China

Marca: xinlin

Certificação: UL,FM,CMA,CNAS

Número do modelo: QMQ5.6/90N-XL-004

Documento: Folheto PDF do produto

Termos de pagamento e envio

Quantidade de ordem mínima: 1

Preço: negotiable

Detalhes da embalagem: Caixa externa de madeira compensada com bolsa de bolha ou papel

Tempo de entrega: 10-15 dias úteis após o pagamento ou recebimento de L/C

Termos de pagamento: L/C,D/A,D/P,T/T,Western Union,MoneyGram

Habilidade da fonte: 20000 conjuntos por semana

Obtenha o melhor preço
Destacar:

Automatic FM200 fire suppression system

,

Large area gas suppression system

,

Internal storage pressure fire system

Pressão de trabalho máxima:
8MPA ((20°C)
Preenchimento da densidade:
≤1080kg/m3
Nome:
Sistema FM200
Tempo de interrupção do sistema:
Sala de computadores ≤ 8s, outros ≤ 10s
Modo de inicialização:
Automático, eléctrico manual, de emergência mecânica
Pressão de armazenamento:
5.6MPA ((20°C)
Espaço do trabalho:
0°C~50°C
Concentração do projeto de extintor de incêndio:
8°10°C
Pressão de trabalho máxima:
8MPA ((20°C)
Preenchimento da densidade:
≤1080kg/m3
Nome:
Sistema FM200
Tempo de interrupção do sistema:
Sala de computadores ≤ 8s, outros ≤ 10s
Modo de inicialização:
Automático, eléctrico manual, de emergência mecânica
Pressão de armazenamento:
5.6MPA ((20°C)
Espaço do trabalho:
0°C~50°C
Concentração do projeto de extintor de incêndio:
8°10°C
Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

 

Product Description:

Heptafluoropropane (HFC-227ea/FM-200) is a colorless, odorless, non-conductive, and no

secondary pollution gas with clean, low toxicity, good electrical insulation, high fire-extinguishing efficiency, particularly its non-ozone destruction , the residence time in the atmosphere is relatively short, its environmental performance is superior to Halon, is by far the more successful research and development of a clean gas extinguishing agent, can be used safely in the workplace has staff also replace Halon's most 1301,1211 one of the ideal product.

Technical Parameters:

Product Name FM200 System
Filling pressure 4.2 MPa
Starting Mode Automatic, Electrical Manual, Mechanical Emergency
System Power Supply AC220V/DC24V/1A
Filling Density ≤1080kg/m3
Scope of Work 0°C~50°C
Storage bottle volume 90L, 120L,150L, 180L
System Blowdown Time Computer Room ≤8s, Other ≤10s
Maximum Working Pressure 5.3MPA(+20°C)



Applications:


Automatic suppression systems based on the FM200 are used in critical areas of significant strategic value. Critical areas are those that house high-cost investment elements and/or are fundamental to the operation of a company or even society.

 The FM200 gas system is widely used to protect:

 · Process control rooms in refineries, gas plants, power plants, petrochemical plants, etc.

 · Substations at power distribution companies and refineries

 · Substations at train and subway stations

 · Railway signal rooms

 · Electrical rooms or distribution rooms

 · Server rooms

 · Telecommunications rooms or communication centers for internet service providers and mobile phone operators

 · Motor control centers (MCCs) in industry and other sectors

· Data centers for banks, oil companies, mining companies, etc.

 · Permanent Gas (PTG) gas and Permanent Petroleum (PTC) oil processing facilities

 · Offshore platform facilities

 · Zoned distribution rooms

· Airport control rooms


Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage 0



Maintenance requirement


Check the system regularly, including the pressure check of the fire extinguishing agent bottle group, generally check the bottle group pressure at least once a month to ensure that the pressure is within the specified range. Check pipes and fittings for leakage, and use soapy water and other methods to detect leakage. It is also necessary to perform functional tests on the electrical components of the system, such as fire detectors, controllers, etc., to ensure that the system can start and operate normally. In addition, every five years should be a comprehensive test of the system, including fire extinguishing agent quality testing.


Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage 1

Why choose us:


• Efficient management system

• More than 10 years of experience in gas fire fighting industry

• Advanced equipment and professional engineers

• We provide 8×6 hr technical support and after-sales service


Frequently Asked Questions

-----------------------------------------------------------------------------------

Q1Are you a manufacturer or a trading company?

A1: We are the manufacturer.


Q2: Do you have OEM orders?

A2: Yes, according to the customer's requirements.


Q3: Where is your factory located? How do I get there?

A3: Our factory is located in Dongzhou Industrial Park, Xintang Town, Zengcheng District, Guangzhou City, Guangdong Province, China.

You are very welcome to visit our factory.